Choose the brand aligned with your industry so we can best serve your needs.
For researchers, scientists, and technical professionals: Your one-stop shop for the complete range of laboratory, production, and safety products and services.
Products, chemical reagents, and accessories designed for partition chromatography; in partition chromatography, components of a liquid mixture/sample are separated using a column that contains a stationary phase that is eluted by a mobile phase.
Small and Specialty Supplier Partner Small and/or specialty supplier based on Federal laws and SBA requirements. Learn More
In The Horizontal Developing Chambers, Hptlc Plates Can Be Developed From Both Opposing Sides Towards The Middle. This Permits The Number Of Samples To Be Doubled As Compared With Development In A Tank, Provided The Separation Distance Of 45 Mm, I.E. 50 Mm Minus 5 Mm Distance From The Edge, Is Sufficient. This Chamber Type Is Often Used For Screening Purposes. The Obtained Chromatograms Differ From Those Obtained With The Same Mobile Phase System Developed In Vertical Chambers. This Chamber Is Suitable For Plates Up To 20 X 10 Cm In Size.
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
Small and Specialty Supplier Partner Small and/or specialty supplier based on Federal laws and SBA requirements. Learn More
For use with sticky matt tape (7740-40000). Dimensions: 20"x20", .050" thick w/ 1/2" lip with pegs. Will fit any Bellco rocker or shaker. Plain tray - no rubber matt.. MADE IN THE USA
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
Small and Specialty Supplier Partner Small and/or specialty supplier based on Federal laws and SBA requirements. Learn More
Fabricated acrylic racks that are designed to fit with Kodak developing tanks. Sheet film is firmly held in the slots in the side rails while solution is freely circulating inside the tank. Measurements 3.5 x 6-7/8 x 6"H. Holds 18 sheets of film 3 1/4 x 4"
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
Small and Specialty Supplier Partner Small and/or specialty supplier based on Federal laws and SBA requirements. Learn More
Sorbtech Rocket TLC Chamber for 2.5 x 7.5cm TLC Plates - an innovative, TLC small-scale development chamber that delivers more efficient, effective, and safer handling of TLC. Solvent consumption is reduced by 80-85%. Rf overruns are eliminated using a reduced solvent. Overall operational time is faster. Results are far more consistent test to test. The TLC plate is always kept in the same orientation. Rocket shape and white background provide easy visualization. Can be used with glass, plastic, and aluminum backed plates.
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
Small and Specialty Supplier Partner Small and/or specialty supplier based on Federal laws and SBA requirements. Learn More
This TLC plate holder is lightweight and made of polypropylene. It is thus highly resistant to contamination or other ill affects from exposure to typical TLC solvents.The sloping bottom grooves guide TLC plates to the vertical grooves which hold plates in an upright position. Holds up to 25 TLC plates of any size. Dimensions: 10.5" x 8.0" x 4.0" (L x W x H)
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
Small and Specialty Supplier Partner Small and/or specialty supplier based on Federal laws and SBA requirements. Learn More
Heavy duty, molded TLC developing tank for use with plates up to 20 x 20 cm ( 8in x 8in). The weight of the tank is approximately 15 pounds, and the bottom is ground to insure stability. Inside dimensions of the tank are 27cm wide x 7cm deep x 26 cm high (10 5/8in x 2 7/8in x 10in). Tank is supplied complete with lid.
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
Small and Specialty Supplier Partner Small and/or specialty supplier based on Federal laws and SBA requirements. Learn More
This Is A Classical Developing Tank For Thin-Layer Chromatography. Compared To A Flat Bottom Chamber Less Solvent Is Needed. A Twin-Trough-Chamber Reduces Disposal Problems And Allows Preconditioning Of The Plate With Any Solvent And For Any Duration. For Preconditioning Or Saturation, The Trough Opposite To The Plate Is Filled With Developing Solvent. The Use Of A Saturation Pad Is Recommended For A Fast, Homogeneous And Reproducible Chamber Saturation Process. This Tank Is Suitable For Plates Up To 20 X 20 Cm In Size.
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More